Introduction
Build an intelligent demand-side management system that automatically schedules and controls loads to minimize peak demand. This comprehensive guide covers everything from design through implementation, testing, and deployment.
Build an intelligent demand-side management system that automatically schedules and controls loads to minimize peak demand.
Build an intelligent demand-side management system that automatically schedules and controls loads to minimize peak demand. This comprehensive guide covers everything from design through implementation, testing, and deployment.
Survey all electrical loads and classify by curtailability: Critical (cannot be interrupted — servers, medical equipment, safety systems), Essential (short interruption acceptable — lighting, ventilation), Sheddable (15-30 min interruption acceptable — EV chargers, non-urgent HVAC), Flexible (timing-flexible — water heaters, refrigeration, dishwashers). Assign priority 1–4 accordingly. Map each load to control hardware (smart plug, relay, or BMS interface).
10 components required for this project.
| # | Component | Purpose | Qty |
|---|---|---|---|
| 1 | Raspberry Pi 4 (DSM Controller) | Central optimization engine | x1 |
| 2 | Smart Plugs with Power Monitoring | Load control and measurement points | x8 |
| 3 | Clamp Current Meter (Main Feed) | Total building demand monitoring | x1 |
| 4 | Demand Controller Relay Panel | HVAC and industrial load control | x1 |
| 5 | DS18B20 Temperature Sensors | Room temperature for HVAC optimization | x4 |
| 6 | Occupancy Sensors (Zigbee) | Presence-based load control | x4 |
| 7 | 4G Router for Utility API | Demand response program integration | x1 |
| 8 | Touchscreen (7" DSM dashboard) | Real-time demand display and override | x1 |
| 9 | Historical Data Server (local) | Pattern learning and forecasting | x1 |
| 10 | Real-Time Pricing API Integration | Tariff-based optimization input | x1 |
Follow these 3 steps carefully.
Survey all electrical loads and classify by curtailability: Critical (cannot be interrupted — servers, medical equipment, safety systems), Essential (short interruption acceptable — lighting, ventilation), Sheddable (15-30 min interruption acceptable — EV chargers, non-urgent HVAC), Flexible (timing-flexible — water heaters, refrigeration, dishwashers). Assign priority 1–4 accordingly. Map each load to control hardware (smart plug, relay, or BMS interface).
Set a maximum demand threshold (e.g., 80% of contract demand to avoid excess demand charges). Monitor instantaneous demand every 5 seconds. When demand approaches threshold (>90%), trigger demand response sequence: shed lowest-priority loads first (EV charger → pool pump → secondary HVAC zones → lighting dimming). Restore loads in reverse order when demand drops below 75% threshold. Implement minimum off-time (15 minutes) for HVAC equipment protection.
Train a gradient boosting model (XGBoost) on 6 months of 15-minute interval demand data. Features: hour of day, day of week, day of year, temperature, humidity, occupancy, calendar events (public holidays, school terms). Target: 15-minute ahead demand in kW. Achieve MAPE < 8% for 1-hour ahead forecast. Use forecasts proactively: if model predicts peak demand period, pre-cool building and pre-charge batteries 30 minutes before.
Core code for dsm_optimizer.py:
import numpy as np from datetime import datetime class DemandOptimizer: def __init__(self, threshold_kw=45): self.threshold = threshold_kw self.loads = { "ev_charger": {"kw": 7.2, "priority": 4, "min_off": 15, "state": True}, "hvac_zone2": {"kw": 3.5, "priority": 3, "min_off": 15, "state": True}, "pool_pump": {"kw": 2.5, "priority": 4, "min_off": 30, "state": True}, "hot_water": {"kw": 4.0, "priority": 3, "min_off": 60, "state": True}, } def optimize(self, current_demand_kw): if current_demand_kw < self.threshold * 0.9: self.restore_loads() return excess = current_demand_kw - self.threshold # Shed loads by priority (highest number first = lowest priority) for name, load in sorted(self.loads.items(), key=lambda x: -x[1]["priority"]): if excess <= 0: break if load["state"]: print(f"Shedding {name} ({load['kw']}kW)") load["state"] = False excess -= load["kw"] def restore_loads(self): for name, load in sorted(self.loads.items(), key=lambda x: x[1]["priority"]): if not load["state"]: print(f"Restoring {name}") load["state"] = True
Test Demand Side Management System by verifying each subsystem individually before full integration.
Verify power voltages, check ground connections, use serial monitor for debug.
An interactive simulator will be available here — simulate circuits and run code in-browser without hardware.